Toilet Partitions – Technical Specifications

Only 13mm Compact Laminate and 18mm Compressed Fibre Cement (CFC) systems are recommended for use in wet and high moisture areas (showers). For shower amenities we also supply shower seats (900mm L x 200mm W standard) and splash nibs (1700-1800mm H x 200mm W standard).

13mm Compact Laminate

13mm Compact Laminate
SizeDimensions
(Standard Sizes)
FixingsHardware includedNotes
Division PanelsToilet divisions 1700mm H x 1500mmW
Shower divisions 1700mm H x 1800mmW
Mounted approx. 200mm off floor
Aluminium channel to rear wall and frontal panels.Stainless steel screwsDivision panels are cut smaller to allow for channel and expansion tolerances
Frontal Panels1800mm H x 300mm W (min. 200mm W)Aluminium channel fixed to division. Supported by 2 single legs.
Nib Panels1800mm H x 150mm W (min. 80mm W)Aluminium channel fixed to wall. Supported by 1 single legNib panels are cut smaller to allow for channel and expansion tolerances
Doors1700mm H x 600mm W (Standard)
1700mm H x 720mm W (Ambulant)
Hinged to the frontals.
Edges cut square as standard
3 Hinges screw fixed per doorRoutered option available for further privacy
HeadrailsStandard round headrail. Square headrail is optionalFixed to frontal and nib panels with provided screwsSnap in inserts to enclose door openingsSupplied oversized to allow docking to suite specific site measurement
Foot Assemblies200mm Nova Adjustable legsNova legs are fixed to floors with screws

18mm Compressed Fibre Cement (CFC)

18mm Compressed Fibre Cement (CFC)

SizeDimensions
(Standard Sizes)
FixingsHardware includedNotes
Division PanelsToilet divisions 1800mm H x 1500mmW
Shower divisions 1800mm H x 1800mmW
Mounted approx. 200mm off floor
Aluminium channel to rear wall and frontal panels. Supported by one single leg.RivetsDivision panels are cut smaller to allow for channel and expansion tolerances
Frontal Panels1900mm H x 300mm W (min. 200mm W)Aluminium channel fixed to division.
Nib Panels1900mm H x 150mm W (min. 80mm W)Aluminium channel fixed to wall.Nib panels are cut smaller to allow for channel and expansion tolerances
Doors1800mm H x 600mm W (Standard)
1800mm H x 720mm W (Ambulant)
Hinged to the frontals.
Edges cut square as standard
2 Bolt through hinges per door
HeadrailsSquare headrailFixed to frontal and nib panels with provided rivetsSnap in inserts to enclose door openingsSupplied oversized to allow docking to suite specific site measurement
Foot Assemblies300mm solid aluminium legHole in drilled into floor and leg is chem set to desired height

18, 25, 33 mm Structure Board

18, 25, 33 mm Structure Board
SizeDimensions
(Standard Sizes)
FixingsHardware includedNotes
Division PanelsToilet divisions 1700mm H x 1500mmW
Shower divisions 1700mm H x 1800mmW
Mounted approx. 200mm off floor
Aluminium channel to rear wall and frontal panels. Supported by one single leg.Stainless steel screwsDivision panels are cut smaller to allow for channel and expansion tolerances
Frontal Panels1800mm H x 300mm W (min. 200mm W)Aluminium channel fixed to division.
Nib Panels1800mm H x 150mm W (min. 80mm W)Aluminium channel fixed to wall.Nib panels are cut smaller to allow for channel and expansion tolerances
Doors1700mm H x 600mm W (Standard)
1700mm H x 720mm W (Ambulant)
Hinged to the frontals.
Edges cut square as standard
3 Hinges screw fixed per doorRoutered option available for further privacy
HeadrailsStandard round headrail. Square headrail is optionalFixed to frontal and nib panels with provided screwsSnap in inserts to enclose door openingsSupplied oversized to allow docking to suite specific site measurement
Foot Assemblies300mm solid aluminium legHole in drilled into floor and leg is chem set to desired height